Hi, Grady. I don't have a print for that model, but have had many Sanyo sets where a high ESR cap to the horizontal driver would cause early failure of the HOT. Usually 4.7@160 or maybe as low as 1ufd. Several I have replaced in various models have been C408, but that is just a starting point. HTH, Ken Smith Gulf Technical Services 3034 Gulf Breeze Parkway Gulf Breeze, FL 32563 850-934-8324 (Voice), 850-932-0819 (fax) On Thu, 2 Dec 2004 02:50:49 EST GOMDWIL@xxxxxxx writes: > Sanyo TV Mod # DS25760 > Chassis # 25760-00 > Mfg. 10/97 > This set came in doa, hot shorted and ac fuse opened. I suspected > the yoke > but the yoke ranged good. I found two bad caps in the vert ckt, but > no other > problems. For test I replaced the HOT (D1879) with a NTE2331 and it > fired up good > for about 5 min. and overheated and shorted out which took out the > ac fuse > again. What am I missing? I have no print. Is there a way to check > this set to > keep from blowing parts? Any help will be appreciated' Thanks, Grady > > Wilson's TV Service > Texarkana, Tx. 75501 > gomdwil@xxxxxxx > > > > ------------------------------------------------------------------------- ---- > Lost Password: > http://www.tech-assist.org and select "Login Problems?". > Email Archives: > //www.freelists.org/archives/techassist/ > > ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/