start with C4105,filter for CR4106. resolder of course. check caps of HOT collector. Peggs At 09:50 AM 4/1/04, Phil Bader wrote: >Originally was dead. I replaced an STK730-010, shorted CR4106, and fuse. >Played days OK. >Customer called, said it would turn off, and on again, like a power >outtage. then OK. Maybe do this 3-6 times a night. Said it went out, >this time he smelled something and saw a bit of smoke come out. >here in shop, I checked it over, 9fuse, HOT good,etc) then I plugged it >in, powered it on with a full good picture/sound EXCEPT: a horizontal >"pie crusting" throughout the picture. I see no evidence of anything >overheated. >Customer is, of course "dismayed and saddened" by this "disturbing" turn >of events. >Need asstsiance please! >Phil Bader > >-- > >Philip Bader >Jan Phyl TV Inc. (estab. 1976) >3420 Recker Hwy. Winter Haven, Fl. 33880 >Fax (863) 299-8821 >email: tjanphyl@xxxxxxxxxxxxxxx > > > >----------------------------------------------------------------------------- >Lost Password: >http://www.tech-assist.org and select "Login Problems?". >Email Archives: >//www.freelists.org/archives/techassist/ ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/