Try replacing C4102 2.2mfd 100v I have found this cap to cause your symptom of increasing B+ Robert supertek66@xxxxxxxxxxx robert_herring@xxxxxxxx H&H Electronics Inc Dallas,Tx. 75233 ----- Original Message ----- From: "Don & Sandra Montgomery" <wrf@xxxxxxxxxxxx> To: "Techassist" <techassist@xxxxxxxxxxxxx> Sent: Saturday, September 15, 2001 6:12 PM Subject: [TechAssist] RCA CTC169cc02 Dead > > Hi all this unit came in dead found Q4101 > shorted,have changed Q4101,CR4122,C4108 > and U4104. > Now standby voltage starts at 140v and rises > to 160v or more. > Any Ideas or help would be very appreciated > Thank so much Don > Hope you all can get over the membership deal > I don't feel I should ask for help BUT I will > try anyway ---HI AL > > > Help make your TechAssist online repair tips > database better! Submit your fixes here: > http://www.circuitwork.com/techassist/tip/#tips > To unsubscribe write to: > techassist-request@xxxxxxxxxxxxx > with unsubscribe in the subject line. > Help make your TechAssist online repair tips database better! Submit your fixes here: http://www.circuitwork.com/techassist/tip/#tips To unsubscribe write to: techassist-request@xxxxxxxxxxxxx with unsubscribe in the subject line.