[TechAssist] Re: RCA CTC169cc02 Dead

  • From: "Robert Herring" <supertek66@xxxxxxxxxxx>
  • To: <techassist@xxxxxxxxxxxxx>
  • Date: Mon, 17 Sep 2001 09:13:32 -0500


Try replacing C4102 2.2mfd 100v I have found this cap to cause your symptom
of increasing B+
Robert
supertek66@xxxxxxxxxxx
robert_herring@xxxxxxxx
H&H Electronics Inc
Dallas,Tx. 75233
----- Original Message -----
From: "Don & Sandra Montgomery" <wrf@xxxxxxxxxxxx>
To: "Techassist" <techassist@xxxxxxxxxxxxx>
Sent: Saturday, September 15, 2001 6:12 PM
Subject: [TechAssist] RCA CTC169cc02 Dead


>
> Hi all this unit came in dead found Q4101
> shorted,have changed Q4101,CR4122,C4108
> and U4104.
> Now standby voltage starts at 140v and rises
> to 160v or more.
> Any Ideas or help would be very appreciated
> Thank so much  Don
> Hope you all can get over the membership deal
> I don't feel I should ask for help BUT I will
> try anyway   ---HI AL
>
>
> Help make your TechAssist online repair tips
> database better!  Submit your fixes here:
> http://www.circuitwork.com/techassist/tip/#tips
> To unsubscribe write to:
> techassist-request@xxxxxxxxxxxxx
> with  unsubscribe  in the subject line.
>
Help make your TechAssist online repair tips 
database better!  Submit your fixes here: 
http://www.circuitwork.com/techassist/tip/#tips
To unsubscribe write to:
techassist-request@xxxxxxxxxxxxx 
with  unsubscribe  in the subject line.