[TechAssist] Re: RCA CTC169Ca intermittent shut down

  • From: "Webster TV" <webstertv@xxxxxxx>
  • To: <techassist@xxxxxxxxxxxxx>
  • Date: Wed, 1 Jan 2003 11:47:05 -0600

Barry,

Had a CTC169 that would play fine and then all of a sudden shutdown, and
then come back on by itself, but I don't think there was any horiz.
instability or arcing sound. The fix was CR4111(#202055), diode comes in a
kit. Just thought I'd mention this.

                                              Dan Webster
                                              Webster's TV
                                              Shullsburg, Wi.
----- Original Message -----
From: Barry MacInnes <foxhole@xxxxxxxxx>
To: Tech Assist <techassist@xxxxxxxxxxxxx>
Sent: Tuesday, December 31, 2002 6:28 AM
Subject: [TechAssist] RCA CTC169Ca intermittent shut down


> This set plays OK for a half hour then looses horizontal stability (arcing
sound eminates from chassis) then shuts down and sometimes comes back on by
itself. replaced CR4118 and C4145. Standbys seem OK, 12v run drops out at
shutdown. Has anyonegot a resolution?
> Thanks,
> Barry
> TV Service Clinic
> W. Lebanon, NH
>
> ------------------------------------------
> Submit A Repair Tip For Everyone Here:
> http://www.tech-assist.org/secure/tip/main.html
> ------------------------------------------
> To REMOVE your email address, click here:
>   http://www.tech-assist.org/unsubb.html
> To CHANGE your email address, click here:
>   http://www.techassist.net/forms/change.html
>

------------------------------------------
Submit A Repair Tip For Everyone Here:
http://www.tech-assist.org/secure/tip/main.html
------------------------------------------
To REMOVE your email address, click here:
  http://www.tech-assist.org/unsubb.html
To CHANGE your email address, click here:
  http://www.techassist.net/forms/change.html