Replace both shorted parts, then replace the 47uf or 39uf cap that is located between the SMPS output and the SMPS drive IC. Damon Brunger damon101@xxxxxxxxxxxxxx Telrad Electronic Services Ft Wayne, IN 46815 ----- Original Message ----- From: "Bill S" <billans@xxxxxxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Monday, November 26, 2001 11:24 PM Subject: [TechAssist] RCA CTC169BG 35" > > Hi all; > We have this unit where another 'retired tech' got into this but did not > have enough muscles and or bench space to go any further with this. > The surge resistor is opened as well as the degauzing thermistor opened > up..... They then gave this unit for me to finish...... The regulator is > shorted. > > Is this the unit that needs the regulator updated modification kit???? If > so .. What is the number of the kit.. > > Much thanks > > Bill > > ================================= > Help make your TechAssist database better! > Submit your fixes here: http://circuitwork.com/techassist/tip/#tips > ================================= > To UNSUBSCRIBE your email address, click here: > mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe > > ================================= Help make your TechAssist database better! Submit your fixes here: http://circuitwork.com/techassist/tip/#tips ================================= To UNSUBSCRIBE your email address, click here: mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe