I plugged it in, pushed power and one HV surge heard, then dead. Push 
power button again and a low arc noise from acassis.
Inspection found scan cap C4401 (.0162@1600V # 206009) had one leg arced 
in solder hole. I replaced it and the set now powers up with good pix 
and sound except it seems bowed on  side like pincushion.