[TechAssist] Re: Philips PTV915. Repeat failure of 7802 (hor.output xstr).

  • From: "Gemini Computer & TV" <geminitv@xxxxxxxxxxx>
  • To: <techassist@xxxxxxxxxxxxx>
  • Date: Tue, 23 Mar 2004 07:08:34 -0500

Possible intermittent CRT (or anode) arc? (Not that a Philips would ever do
that)

Bob Waterman, CET® #RI-28
Master Technician License #9109
Service Manager / Parts Manager
Gemini Computer, TV, & Security Alarms
(508)695-7302
(508)695-7769 FAX
geminitv@xxxxxxxxxxx
geminitv@xxxxxxx
www.geminicomputertvsecurityalarms.com


----- Original Message ----- 
From: "Robinson Electronics" <RobinsonElectronics@xxxxxxxxxxx>
To: <techassist@xxxxxxxxxxxxx>
Sent: Monday, March 22, 2004 9:27 PM
Subject: [TechAssist] Philips PTV915. Repeat failure of 7802 (hor.output
xstr).


> Has anyone had to replace the (ssb) small signal board for a repeat
failure
> of the hor. output xstr?
> (Shorts out after about 1 hr.), picture is good while playing.
> Originally the 7802 - hor.out xstr, flyback xfmr, D6806, and a open
resistor
> was replaced, played then for about a month. Replaced the shorted 7802
> again, played for about 1 hr. (then shorts out).
> Any info. on this appreciated.     Thanks.    David.
>
> Robinson Electronics
> 1075 Sweeten Creek Road
> Asheville, NC 28803
> Ph./Fax. 828  274-3787
> Toll Free. 866-899-3787
> www.robinsonelectronics.com
> www.robelect.com
> Mailto: RobinsonElectronics@xxxxxxxxxxx
>
>
>
> --------------------------------------------------------------------------
---
> Lost Password:
> http://www.tech-assist.org  and select "Login Problems?".
> Email Archives: