[TechAssist] PIP Bypass In The Download Area : Faulty!

  • From: "Shoreline Electronics" <jstielau@xxxxxxxx>
  • To: "Tech Assist" <techassist@xxxxxxxxxxxxx>
  • Date: Thu, 27 Jan 2005 16:44:36 -0500

The PIP bypass diagram in the download directory has an error!!  The 22K ohm 
resistor should go from pin 11 to ground.  NOT PIN 7!  Pin 8 is ground and 
can be used!

I actually used 4.7K and 2.2K for the voltage dividing network per previous 
documented procedures......but I assume the 47K & 22K combo/dividing ratio 
is equivalent.





=================================
Jeff Stielau
Shoreline Electronics Repair
344 East Main Street
Clinton,CT 06413
(860)399-1861
(860)664-3535 FAX
jstielau@xxxxxxxx
================================= 


-----------------------------------------------------------------------------