[TechAssist] Re: Mit VS-5041 Hot keeps blowing

  • From: "J Silverman" <greentron@xxxxxxxxxxxxxxxx>
  • To: <techassist@xxxxxxxxxxxxx>
  • Date: Thu, 9 May 2002 14:28:57 -0400

Have seen some posts saying that due to a deflection problem the electron
beam was striking the tube neck causing it to crack. Also talked with a
technician that was operating a large screen TV with the crt socket off as a
troubleshooting procedure and an arc came out of the tube neck and cracked
it.
Jerry Silverman
Greentron Inc
4 Newland Ave
Greenville SC 29609
864 232 3889
Fax 271 2080
mailto:greentron@xxxxxxx
----- Original Message -----
From: "tomlee" <t8872695@xxxxxxxxxxxxx>
To: <techassist@xxxxxxxxxxxxx>
Sent: Thursday, May 09, 2002 11:54 AM
Subject: [TechAssist] Mit VS-5041 Hot keeps blowing


> Hello freiends.
> I am working with this bigscreen. VS-5041.  Hot and fuse keeps blowing.
searching for bad component I find out the red tube has neck broken.have
never seen this problem why tube broken without phisical impact. Does any
have experience in
> changing the tube ? I am willing to buy a red tube for it with a fair
price. does any have it in the boneyard.
> Dang
> TD electronics
> 18546 sherman way
> reseda , ca 91335
> www.tvcrcomputers.com
>
> ------------------------------------------
> To REMOVE your email address, click here:
>   http://www.tech-assist.org/unsubb.html
> ------------------------------------------
> ***NEW*** Tips Added Instantly!!!***
> Submit Repair Tips here:
> http://www.tech-assist.org/secure/tip/
>

------------------------------------------
To REMOVE your email address, click here:
  http://www.tech-assist.org/unsubb.html
------------------------------------------
***NEW*** Tips Added Instantly!!!***
Submit Repair Tips here: 
http://www.tech-assist.org/secure/tip/