Is checking .164 in ONE direction? Thats the important thing! If so, and
open the other way,it's OK.
Maybe some small electrolytic caps in the PS bad.
Phil Bader

al m wrote:
> 
> This thing works but in standby the switch mode is buzzing. Found 6V on the 
> input to 5V regulator. Disconnected regulator and get 11V. Replaced regulator 
> and same thing.Can anyone tell the part numbers for these diodes D631, D611, 
> D612. These are checking .164 on the diode scale. Don't know if that is right 
> or they are leaky. Need to know what to replace them with. Can't find any 
> crosses for the numbers. Strange that it would work like this.
> al marquardt
> ampm@xxxxxxx
> Al Marquardt Electronic Repair
> 206 W Main
> Girardville Pa. 17935
> *****************************************************************************
> The Tech Address Book:
> http://www.tech-assist.org/secure/tip/contact.html
> Add a Repair Tip Here, or Change/Remove your Email Address:
> http://www.tech-assist.org/secure/tip/main.htm
> Lost Password:
> http://www.tech-assist.org  and select "Lost your Login Info?".
> Email Archives:
> //www.freelists.org/archives/techassist/

-- 
Philip Bader
Jan Phyl TV Inc. (estab. 1976)
3420 Recker Hwy. Winter Haven, Fl. 33880
Fax (863) 299-8821      
email: tjanphyl@xxxxxxxxxxxxxxx

*****************************************************************************
The Tech Address Book:
http://www.tech-assist.org/secure/tip/contact.html
Add a Repair Tip Here, or Change/Remove your Email Address:
http://www.tech-assist.org/secure/tip/main.htm
Lost Password:
http://www.tech-assist.org  and select "Lost your Login Info?".
Email Archives:
//www.freelists.org/archives/techassist/

Other related posts: