Mode switch is not cleaned properly or is defective. The internal fingers 
that contact the trace may not have enough tension.
Paul W
C&W Electronics

From: "Barry Appleby" <burintv@xxxxxxxxxxx>
Reply-To: techassist@xxxxxxxxxxxxx
To: techassist@xxxxxxxxxxxxx
Subject: [TechAssist] GE vcr model# VG4264
Date: Tue, 16 Oct 2001 17:08:17 -0230


All functions will operate ok except it goes into fast forward when the play
or record buttons are pressed . I cleaned the audio control head , mode
switch and  replaced the end sensors and center led but got no luck . The
vc93 test tape shows the control pulse is there and doesn't appear to have a
servo problem  . It doesn't seem to be out of time as it loads and unloads
ok . The capastan motor is operating at fast forward speed in the play
position . Does anyone have a suggestion on what I could try next . Thanks
again .                       Barry Appleby .
                          Burin tv & vcr repair
                      burintv@xxxxxxxxxxx
                 {709}891-2356

_________________________________________________________________
Get your FREE download of MSN Explorer at http://explorer.msn.com/intl.asp

Help make your TechAssist online repair tips
database better!  Submit your fixes here:
http://www.circuitwork.com/techassist/tip/#tips
To unsubscribe write to:
techassist-request@xxxxxxxxxxxxx
with  unsubscribe  in the subject line.


_________________________________________________________________
Get your FREE download of MSN Explorer at http://explorer.msn.com/intl.asp

Help make your TechAssist online repair tips 
database better!  Submit your fixes here: 
http://www.circuitwork.com/techassist/tip/#tips
To unsubscribe write to:
techassist-request@xxxxxxxxxxxxx 
with  unsubscribe  in the subject line.

Other related posts: