Three click I would ring the flyback. Every three clicker I've had was the
flyback. Also did you check the timing on the HOT circuit. Maybe bad Timing
cap.
Al Marquardt
ampm@xxxxxxx
Al Marquardt Electronic Repair
206 W Main
Girardville Pa. 17935
----- Original Message ----- 
From: "Phil Bader" <tjanphyl@xxxxxxxxxxxxxxx>
To: <techassist@xxxxxxxxxxxxx>
Sent: Tuesday, February 24, 2004 1:37 PM
Subject: [TechAssist] GE 25GT522, CTC177AF2 powers up 3 times,dead.


> Plug it in, the SMPS has the usual chirp, and the HOT collector is at
> about +148 VDC in standby. Push power while monitoring the HV anode and
> it turns on, HV comes up to about 25KV, instantly clicks off, clicks on
> again in half second, off, then a third try, then dead. I didn't see a
> bad fly with HV coming up OK.
>  I checked all diodes, found no shorts.
> Histories?
>