Three click I would ring the flyback. Every three clicker I've had was the flyback. Also did you check the timing on the HOT circuit. Maybe bad Timing cap. Al Marquardt ampm@xxxxxxx Al Marquardt Electronic Repair 206 W Main Girardville Pa. 17935 ----- Original Message ----- From: "Phil Bader" <tjanphyl@xxxxxxxxxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Tuesday, February 24, 2004 1:37 PM Subject: [TechAssist] GE 25GT522, CTC177AF2 powers up 3 times,dead. > Plug it in, the SMPS has the usual chirp, and the HOT collector is at > about +148 VDC in standby. Push power while monitoring the HV anode and > it turns on, HV comes up to about 25KV, instantly clicks off, clicks on > again in half second, off, then a third try, then dead. I didn't see a > bad fly with HV coming up OK. > I checked all diodes, found no shorts. > Histories? > > Phil > > -- > > Philip Bader > Jan Phyl TV Inc. (estab. 1976) > 3420 Recker Hwy. Winter Haven, Fl. 33880 > Fax (863) 299-8821 > email: tjanphyl@xxxxxxxxxxxxxxx > > > > > -------------------------------------------------------------------------- --- > Lost Password: > http://www.tech-assist.org and select "Login Problems?". > Email Archives: > //www.freelists.org/archives/techassist/ > > ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/