Kevin,
First thing to check:
From Tech Repair CD;
GEN ELECTRIC\19TVR60\GOES DEAD IN 5 SECS.\\\\MODE SWITCH- CHECK ALIGNMENT- 
CHECK PINCH ROLLER
PLACEMENT\\\\\\\\\
Another common problem is shorted motor driver IC.

Jeff Dougherty
Intrepid Video TV/VCR
263 S Front St
Steelton PA 17113
fax...717-564-4952
www.intrepid-video.com www.tech-repair.net

----- Original Message -----
From: "Kevin" <kevintv@xxxxxxx>
To: "TECH-ASSIST" <techassist@xxxxxxxxxxxxx>
Sent: Wednesday, November 26, 2003 3:44 AM
Subject: [TechAssist] GE 19TVR60 TV/VCR,TVR2/2A, dead, 6 years old


Customer said that set went dead as the set was on.  No tape was in the
VCR.  When first powered up, relay clicks on and off, HV for a split
second.  Set then goes into shutdown.  B+ is 119.4 volts before power
button is pressed, after power button is pressed, B+ drops to 2 volts as
set goes into shutdown.  Could not find any shorts or open resistors.
All caps checked good for ESR.  TIA

Kevin Wilks
Kevin's TV & Video Repair
Penticton BC Canada
kevintv@xxxxxxx



*****************************************************************************