[TechAssist] Fw: mAGNAVOX 32g700 shuts down 3 seconds

  • From: Al L <alleathe@xxxxxxxxxxxxx>
  • To: techassist@xxxxxxxxxxxxx
  • Date: Thu, 19 Feb 2004 21:37:55 -0500

Sent: Thursday, February 19, 2004 9:37 PM
Subject: mAGNAVOX 32g700 shuts down 3 seconds


> Mag 32g700 shuts down 3 seconds
> hv goes 25kv    
> col voltage up
> distorted output pulses on collector
> replaced vert out and -13 and +18 a little low
> current way up before shut down
> 
> I am suspecting flyback.Ideas? Appreciate help.
> 
> Al Leatherman
> 224 RT. 46
> Mine Hill, NJ 07803
> 973-361-5796
> WWW.ALS-TV.NET
> 
> 
> 
> 

-----------------------------------------------------------------------------