Do you know the reference designators of those 3 cap?  Sure would help me 
out.
Thanks,
Jerry

In a message dated 1/5/02 5:53:02 AM US Mountain Standard Time, 
alterego@xxxxxxxxxxx writes:


> JERRY,Change the three caps just behind the
> vertical heat sink,very common problem on
> panasonics,(even though they may check ok)
> seems I ran that course once also..Kerry
> KER-TEK TV,Medford, Or
> -----Original Message-----
> From: knitrngr65@xxxxxxx <knitrngr65@xxxxxxx>
> To: techassist@xxxxxxxxxxxxx <techassist@xxxxxxxxxxxxx>
> Date: Friday, January 04, 2002 9:18 PM
> Subject: [TechAssist] Panasonic CT 20G 22V (Vertical Fold Over)
> 
> 
> >To begin with set had vertical line.  Replaced vertical deflection IC.
> >Restored vertical collapse problem.  Now set has vertical fold over.
> Checked
> >all electro. caps, all of them checked good.  Does anyone have any ideas 
> on
> >this one?  working without schem.
> >
> >Thanks,
> >Jerry
> >
> >
> >
> >------------------------------------------
> >Help make your TechAssist database better!
> >Submit your fixes here: http://circuitwork.com/techassist/tip/#tips
> >------------------------------------------
> >To UNSUBSCRIBE your email address, click here:
> >mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe
> >Or send a BLANK email with unsubscribe in the
> >SUBJECT field to the address above.
> >
> 
> ------------------------------------------
> Help make your TechAssist database better!  
> Submit your fixes here: http://circuitwork.com/techassist/tip/#tips
> ------------------------------------------
> To UNSUBSCRIBE your email address, click here:
> mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe
> Or send a BLANK email with unsubscribe in the
> SUBJECT field to the address above.
> 
> 




------------------------------------------
Help make your TechAssist database better!  
Submit your fixes here: http://circuitwork.com/techassist/tip/#tips
------------------------------------------
To UNSUBSCRIBE your email address, click here:
mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe
Or send a BLANK email with unsubscribe in the
SUBJECT field to the address above.

Other related posts: