[TechAssist] Re: Fw: Observation/warning on pro jo shut down on jigs/Powerites

  • From: "James M. Knoble" <jmk1938@xxxxxxxxxx>
  • To: techassist@xxxxxxxxxxxxx
  • Date: Wed, 7 Sep 2005 17:52:13 -0400

CTC179 does not always start up on an autotransformer



On Wed, 07 Sep 2005 15:14:10 -0400, AL LEATHERMAN wrote
> Sent: Wednesday, September 07, 2005 3:13 PM
> Subject: Observation/warning on pro jo shut down on jigs/Powerites
> 
> >I have seen several incidents of APPARENT shut down on pro jos on my 
> >plastic pipe rig(guts only),powered by one of my Powerites(Sencore) or my 
> >brand X similar to Powerites. Apparently they draw almost the maximum 
> >current and cause the isolation transormer to go into automatic cut 
> >off.(thermal breaker?) On both these jobs,I simply pluged directly into my 
> >AC outlets,and no more problem.Any similar out there?  al
> >
> > Al's TV
> > Mine Hill, NJ. 07803
> > 972-361-5796
> > WWW.ALS-TV.NET
> 
> -----------------------------------------------------------------------------
> This Email List is accessible to the general public through search 
> engines. Remove: http://www.tech-assist.org/remove.htm Set Vacation
mailto:ecartis@xxxxxxxxxxxxx?subject=set%20techassist%20vacation
> Lost Password: http://www.tech-assist.org  and select "Login Problems?".
> Email Archives: //www.freelists.org/archives/techassist/


--------------------------
James M. Knoble
jmk1938@xxxxxxxxxx
P: 304-366-1938
F: 304-367-8965
--------------------------
KnobleNet Webmail 
(http://www.knoble.org)

-----------------------------------------------------------------------------
This Email List is accessible to the general public through search engines. 
Remove: http://www.tech-assist.org/remove.htm
Set Vacation mailto:ecartis@xxxxxxxxxxxxx?subject=set%20techassist%20vacation
Lost Password: http://www.tech-assist.org  and select "Login Problems?".
Email Archives: //www.freelists.org/archives/techassist/

Other related posts: