Tony-If I wanted to test the supplt out of set,what kind of load would be good and how many watts should this supply provide?{can provide}-pete tony saracco <tcselectronics@xxxxxxxxxxxxxxxx> wrote:Set came in dead. Found blown H out and failed supply. replaced the output with C5148 and the regs Q 601 and Q 602 plus the fusible resistor. After 5 min the reg would get extremely hot and destroy themselves. Replaced the regs, all 8 glass type diodes, all Mylar and ceramic caps on primary, the varistor and the bird tird caps ( .47uf tantalum) but still regs would get hot. Only thing left was the Reg drive transformer T603, After replacing T603 supply runs at much cooler temp and has not failed . Tony Saracco TCS ELECTRONICS Elgin , IL 60120 847-695-1928 tcselectronics@xxxxxxxxxxxxxxxx ***************************************************************************** Classifieds! Buy or Sell! http://sell.tech-assist.org The Tech Address Book: http://www.tech-assist.org/secure/tip/contact.htm Add a Repair Tip Here, or Change/Remove your Email Address: http://www.tech-assist.org/secure/tip/main.htm Lost Password: http://www.tech-assist.org and select "Lost your Login Info?". Email Archives: //www.freelists.org/archives/techassist/ ***************************************************************************** Classifieds! Buy or Sell! http://sell.tech-assist.org The Tech Address Book: http://www.tech-assist.org/secure/tip/contact.htm Add a Repair Tip Here, or Change/Remove your Email Address: http://www.tech-assist.org/secure/tip/main.htm Lost Password: http://www.tech-assist.org and select "Lost your Login Info?". Email Archives: //www.freelists.org/archives/techassist/