[TechAssist] Fixed KV35S36 - Thermal runaway

  • From: "tony saracco" <tcselectronics@xxxxxxxxxxxxxxxx>
  • To: <techassist@xxxxxxxxxxxxx>
  • Date: Mon, 6 Oct 2003 18:14:36 -0500

Set came in dead. Found blown H out and failed supply. replaced the  output 
with C5148 and the regs Q 601 and     Q 602 plus the fusible resistor. After 5 
min the reg would  get extremely hot and destroy themselves. Replaced the regs, 
all 8 glass type diodes, all Mylar and ceramic caps on primary, the varistor 
and the bird tird caps ( .47uf tantalum) but still regs would get hot. Only 
thing left was the Reg drive transformer T603, After replacing T603 supply runs 
at  much cooler temp and has not failed .
Tony Saracco
TCS ELECTRONICS
Elgin , IL 60120
847-695-1928
tcselectronics@xxxxxxxxxxxxxxxx
*****************************************************************************