First thing is to determine if the 124vdc B+ supply from your STR30110 is still OK.Lift pin 9 on fbt & recheck your B+ at pin 4 of the STR. Don of HARTS-TVCR''ASC'' 9 Robert St,Oromocto,NB,Can,E2V3N2 hartstv@xxxxxxxxxxx Tel-5063579785,fax-3576010 cel-4701719 ----- Original Message ----- From: "Dave Koch" <mixerdrv@xxxxxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Tuesday, February 24, 2004 10:38 AM Subject: [TechAssist] Emerson TV TC2556DA > Hi, Set came with no Vert.Replaced vert. chip LA7838 by removing the heat > sink along with the chip > When I put the heat sink back in I didnt pay enough attention and it came > into contact with the heat sink the Regulator is on. Started the set the > heat sinks sparked and set went dead. Replaced both Reg. and Vert. chip, the > HOT seems to be OK, only 10v on the Coll. though. Cant seem to find any > componants bad. Could it have taken out the FB. Thanks, Dave > > Koch Electronics > > _________________________________________________________________ > Say "good-bye" to spam, viruses and pop-ups with MSN Premium -- free trial > offer! http://click.atdmt.com/AVE/go/onm00200359ave/direct/01/ > > > -------------------------------------------------------------------------- --- > Lost Password: > http://www.tech-assist.org and select "Login Problems?". > Email Archives: > //www.freelists.org/archives/techassist/ > ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/