From WINSTIPS:

---------------------------------------------------------------
Text pasted from WinSTIPS 2.0
http://www.ServiceSoftware.com
---------------------------------------------------------------

EMERSON   MS2580RDA

Dead - Click Only  No Snd Or Picture

Bryn Mawr Tv

R502  (1.8 Ohm 7watt)  R518 (5.6 Ohm  7watt)  Q401 2sd1556  C435  1uf/160v

---------------------------------------------------------------

EMERSON   MS2580RDA

Dead Set

Ms2580rda                    Sams:2643-1

Q401 Horz Output Transistor

---------------------------------------------------------------

EMERSON   MS2580RDA

Dead.

Ford'S Tv & Video Service

Shorted Hot, Q401 (2sd1555), And Open Resistor, R518 (4.7 Ohm 5 W).

---------------------------------------------------------------

EMERSON   MS2580RDA

H.o.t. runs hot after replacement, even with new h driver electrolytic

Phil Bader  Jan Phyl Tv

Obtain an ORIGINAL H.o.t. 2sd1556 from Emerson and it runs cooler. Still may
be necessary to attach an additional heat sink. (original emerson hot was
Toshiba brand- avail from B&D)

---------------------------------------------------------------

EMERSON   MS2580RDA

H.o.t. runs hot after replacement..

Russ White suretech@xxxxxxxx

Besides bolting on an additional heatsink, i usually change the resistor
from the base of horiz output from a 1k-1/4w to a 330-1/4w

---------------------------------------------------------------

EMERSON   MS2580RDA

Horiz Output Repeat Failure, Heatsink Too Hot

Q402 2sc2621, C444 .012/2kv, C445.0012/2kv, C437560pf/2kv, C435 1/160, Q401
2sd1556 H.O.T. Must use Toshiba brand h.o.t. avail from B&D a china brand
will work if larger heatsink added to h.o.t. heatsink.

---------------------------------------------------------------

EMERSON   MS2580RDA

Horizontal Output Transistor Repeat Failure.

Ford'S Tv & Video Service

Loose Connection On 125v Input Pin Of Flyback.

---------------------------------------------------------------

EMERSON   MS2580RDA

Hot Overheats

Greg Boyd

C401 & C408: 3.3 Ufd @ 50v ( I Used 10 Ufd ) C405: 47 Ufd @ 16v

---------------------------------------------------------------

EMERSON   MS2580RDA

Hv Shutdown, Immediate

A Helper Elect

C452 100/160, Also Replace C435 1/160

---------------------------------------------------------------

EMERSON   MS2580RDA

Pix & Sound Inop. Ticking, Buzz

From Cgs Elect

25v Line Measures 10v. Ic401 Shorted. Upc1398h Vert Output

---------------------------------------------------------------

EMERSON   MS2580RDA

Pix And Sound Inop. Relay Clicks

Randy Evans

C435 1/160, C452 100/160, Resolder R403, R436, R439, R441, R445, R446,
R505, R506

---------------------------------------------------------------

EMERSON   MS2580RDA

Shorting Of Horizontal Output Transistor, Transistor Runs Hot

Ms2580rda                    Sams:2643-1

T401 Horz Driver Transformer

---------------------------------------------------------------

EMERSON   MS2580RDA

Shutdown (Int) With Clicking

B&W Elect

Solder Bad At Cf401 503 Khz Xtal. Off Ic201-62

---------------------------------------------------------------

EMERSON   MS2580RDA

Ticking, No Sound or Pix

Georges Tv & Vcr Ser Phx Az

Q401 2sd1556,Sub Bu2508df (10a), C435 R518 1/160v, R518  5.6 Ohm 7w Also Chk
Connections On Dr Transformer.

---------------------------------------------------------------

EMERSON   MS2580RDA

Ticking, Nsnp

Q401 2sd1556, R518 5.6 Ohm 10w

---------------------------------------------------------------

EMERSON   MS2580RDA

Ticking,Intermittent Shut Down

Earls Tv Naperville Il

Resolder All Connections On Horiz Flyback Also Check For Bad Solder  On
Associated Power Resistors In Horz Area Connections On Vert Cent Pot Were
Bad

---------------------------------------------------------------

Bob Waterman, CET® #RI-28
Master Technician License #9109
Service Manager
Gemini Computer, TV, & Security Alarms
(508)695-7302
(508)695-7769 FAX
geminitv@xxxxxxxxxxxxxxxx
geminitv@xxxxxxx

----- Original Message -----
From: "C&W Electronics" <c_w_electronics@xxxxxxxxxxx>
To: "Tech Assist" <techassist@xxxxxxxxxxxxx>
Sent: Wednesday, January 15, 2003 10:42 PM
Subject: [TechAssist] Emerson HOT running hot & shorting.


> Model MS2580RDA, Q551(2SD1556) shorted, R518(5.6 ohm 7w) open,
C435(1uf/160v) open, replaced defective parts, resoldered defective
connections.
>
> Q551 gets hot after 5 min, with slight pulling in on right side, would
short if left on. Flyback and Yoke sweep good and run cool. In Sams 2643-1
>
> Any ideas as to cause of excess heat and pulling would be appreciated.
>
> Paul W
> C&W Electronics
> Azle Texas
> ------------------------------------------
> Submit A Repair Tip For Everyone Here:
> http://www.tech-assist.org/secure/tip/main.html
> ------------------------------------------
> To REMOVE your email address, click here:
>   http://www.tech-assist.org/unsubb.html
> To CHANGE your email address, click here:
>   http://www.techassist.net/forms/change.html
>
>

------------------------------------------
Submit A Repair Tip For Everyone Here:
http://www.tech-assist.org/secure/tip/main.html
------------------------------------------
To REMOVE your email address, click here:
  http://www.tech-assist.org/unsubb.html
To CHANGE your email address, click here:
  http://www.techassist.net/forms/change.html

Other related posts: