That would be the same as a Memorex in the US. You may need to have the original regulator that has an internal connection to pin 5 (usually pin 5 is open). The output voltage should be 136.6v and the V on pin 2 should be 137.3v. Also check R506 (180-20watt) and R507 (47 ohm-quarter watt) and C519 (10uf- 160v). How did the regulator fail originally, short or open? John. John Mielke Main TV 636 main St. Longmont, Co phone 303 776 6955 fax 303 776 0792 maintv2004@xxxxxxxxxxx ----- Original Message ----- From: "D Trippel" <dtrippel@xxxxxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Wednesday, June 09, 2004 3:41 PM Subject: [TechAssist] DBTV2500 Repeat failure IC501 > Hello Everyone! > > I Have a couple of Durabrand DBTV2500 tv's that have repeat failure of > ic 501 str30110 reg , R506 20w , R 508 and Q 401 hot. Both of these > sets ran about a month and are back. Same problem. Has anyone out there > found the cause . I have checked a variety of components in the reg > circuit , and other than the parts listed everything checks out fine. > Any help would be appreciated. > Don trippel > Don's Electronics > Rosthern,Sask > Canada > > > > -------------------------------------------------------------------------- --- > Lost Password: > http://www.tech-assist.org and select "Login Problems?". > Email Archives: > //www.freelists.org/archives/techassist/ > ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/