[TechAssist] Re: CTC177 SMPS

  • From: "Charles Belich" <seashell@xxxxxxxxxx>
  • To: <techassist@xxxxxxxxxxxxx>
  • Date: Tue, 11 Sep 2001 20:45:15 -0700

Check pin 7 of switching transformer for bad solder etc. C4107 may be bad.
Check C4105............Charlie

Charles Belich
Slidewire Electronics
MN seashell@xxxxxxxxxx

----- Original Message -----
From: "sterling pasher" <spasher@xxxxxxxxxxxxxxxxx>
To: <Techassist@xxxxxxxxxxxxx>
Sent: Tuesday, September 11, 2001 1:39 PM
Subject: [TechAssist] CTC177 SMPS


>
>         I have a CTC177that is putting out too much voltage from power
> supply, ithas only to be plugged in to AC. At test point 4101  get 340
> vvolts(should be 140) If left on for more  than a sexcond it will cause
pins
> 4 and 5 to short. And causes C4107 to explode. Besides U4101 changed R4110
> (open) and  R4126 (burnt).
>
>
>         Any help on this ptoblem would be appreciated .
>
>                                                                 Buck
>
> Help make your TechAssist online repair tips
> database better!  Submit your fixes here:
> http://www.circuitwork.com/techassist/tip/#tips
> To unsubscribe write to:
> techassist-request@xxxxxxxxxxxxx
> with  unsubscribe  in the subject line.
>
>

Help make your TechAssist online repair tips 
database better!  Submit your fixes here: 
http://www.circuitwork.com/techassist/tip/#tips
To unsubscribe write to:
techassist-request@xxxxxxxxxxxxx 
with  unsubscribe  in the subject line.

Other related posts: