[TechAssist] Re: CTC169PTV

  • From: "al m" <ampm@xxxxxxx>
  • To: <techassist@xxxxxxxxxxxxx>
  • Date: Sat, 9 Oct 2004 08:07:35 -0400

If you Changed the caps in the regulator then disconnect the lead from the 
flyback to the splitter and see if it turns on.
Al Marquardt
ampm@xxxxxxx
Al Marquardt Electronic Repair
206 W Main
Girardville Pa. 17935
----- Original Message ----- 
From: "S. Pasher" <spasher@xxxxxxxxxxxxx>
To: <techassist@xxxxxxxxxxxxx>
Sent: Friday, October 08, 2004 5:25 PM
Subject: [TechAssist] CTC169PTV


> Got the SMPS going but its 157 volts on col of H/O without turn on. When I
> press ON it goes down but set turns off and it goes back up. The Horz.
> derived voltage come up for a moment but go right back down, which means 
> its
> trying to start.I'm wondering if my orginal 157 volts is too high? I got 
> to
> change a few of the (required) caps yet but would anyone have any tips on
> this one.
>
> Buck Pasher
> Buck's TV
> Gander Newfoundland
> Canada
> 709-256-7738 (Fax & Phone)
>
>
>
>
> -----------------------------------------------------------------------------
> Lost Password:
> http://www.tech-assist.org  and select "Login Problems?".
> Email Archives:
> //www.freelists.org/archives/techassist/
>
> 



-----------------------------------------------------------------------------
Lost Password:
http://www.tech-assist.org  and select "Login Problems?".
Email Archives:
//www.freelists.org/archives/techassist/

Other related posts: