B+ is too high in standby and regulated. maybe you got a bad part. Al Marquardt ampm@xxxxxxx Al Marquardt Electronic Repair 206 W Main Girardville Pa. 17935 ----- Original Message ----- From: "Intrepid Video Support" <support@xxxxxxxxxxxxxxxxxx> To: "Techassist" <techassist@xxxxxxxxxxxxx> Sent: Monday, March 08, 2004 1:18 PM Subject: [TechAssist] 2nd request. PTK169PAAS..Shutsdown. > Still working on this, can not figure out why it is shutting down as HV builds. > Would a defective vertical section cause this set to shut down? > REG B+ is 170 in standby, drops to 162 when I press power..is this normal on this set? > Schematic shows Reg B+ <72-A>, Not sure what that means. > I've repaired many of these with a splitter, flyback or replacing the parts in the power supply. > I've done all this and set still shuts. I've replaced all the caps, the boxed caps in front of the HOT, > CR4118(tested OK), U4101, Q4101, Q4401..and all the caps. Checked all the diodes and resistors and can > find no problems. > I'm running out of time on this one....Does anyone have any idea what I may have missed? > Thank you. > > Jeff Dougherty > Intrepid Video TV/VCR > 263 S Front St > Steelton PA 17113 > fax...717-564-4952 > www.intrepid-video.com www.tech-repair.net > > > -------------------------------------------------------------------------- --- > Lost Password: > http://www.tech-assist.org and select "Login Problems?". > Email Archives: > //www.freelists.org/archives/techassist/ > > ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/