> i have a question.i have a clock buffer which o/p's 4 copies of 100mhz > ttl clocks,i am using only 2 of them do i need to terminate the rest of > the clocks which i am not using.if so which termination is good.if > unconnected dont they radiate and upset the nearby traces. Why do you think they would radiate? (Any more than with terminations?) Terminating them makes the output current >0, so if anything there might be more (magnetic) radiation. If the outputs were complementary (differential), then you might need to terminate both sides of each pair about the same, so that you don't upset the current balance in the chip. Also I have seen an ECL chip where the vendor wanted certain unused outputs terminated, in order to preserve clock skews (on the order of 50ps). Your best bet: ask the vendor. Andy ------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List archives are viewable at: //www.freelists.org/archives/si-list or at our remote archives: http://groups.yahoo.com/group/si-list/messages Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu