[SI-LIST] Re: symmetry vs length matching for diff signals

  • From: "Jim Antonellis" <janton@xxxxxxxxxxxxx>
  • To: <lambert@xxxxxxxxxxxxxxxxxx>, <Cortex.Chen@xxxxxxxxxxxx>, "Kai Keskinen" <kalevi@xxxxxxxxxx>, <ricbrook@xxxxxxxxx>
  • Date: Wed, 1 Dec 2004 15:30:04 -0500

Bert,

Thanks for the quick example data.

Does the format of your geometry, "x-y-x", represent:
        etch-width, air-gap, etch-width?

What was the distance from the reference plane for the etch?

Thx,
Jim

-
Jim Antonellis   janton@xxxxxxxxxxxxxxxxxx
Sandburst Corp   www.sandburst.com
Office: 978.689.1669
Cell: 978.618.4745

This message and any attachments are Confidential and may be Legally
Privileged. It is intended solely for the addressee. If you are not
the intended recipient, please delete this message from your system
and notify us immediately. Any dis-closure, copying, distribution or
action taken or omitted to be taken by an unintended recipient in
reliance on this message is prohibited and may be unlawful.



-----Original Message-----
From: si-list-bounce@xxxxxxxxxxxxx
[mailto:si-list-bounce@xxxxxxxxxxxxx]On Behalf Of Bert Simonovich
Sent: Wednesday, December 01, 2004 9:46 AM
To: 'Cortex.Chen@xxxxxxxxxxxx'; Kai Keskinen; ricbrook@xxxxxxxxx
Cc: si-list@xxxxxxxxxxxxx
Subject: [SI-LIST] Re: symmetry vs length matching for diff signals


Another way to determine coupling is when odd mode impedance (Zodd) is much
less than even mode impedance (Zeven), the pairs are considered close
coupled. The closer Zodd is to Zeven, the looser the coupling.
For a given stripline geometry where trace widths and reference plane
heights are constant, moving the traces closer together reduces the odd mode
impedance while increasing the even mode impedance thereby increasing the
coupling coefficient Kc. The Knee for Kc(min) is when Zodd equals Zeven.
Increasing the separation past the Knee does not significantly decrease Kc,
and each trace can be considered as single ended trace for impedance.

To give you the idea, I have run some quick examples;

5-5-5  geometry: Zodd = 39.8 ohms; Zeven = 48.5 ohms; Kc = 9.8%
5-10-5 geometry: Zodd = 46.1 ohms; Zeven = 48.0 ohms; Kc = 2.0%
5-15-5 geometry: Zodd = 44.4 ohms; Zeven = 44.0 ohms; Kc = 0.5%
5-20-5 geometry: Zodd = 46.5 ohms; Zeven = 46.6 ohms; Kc = 0.1%

Regards,

Bert Simonovich

-----Original Message-----
From: si-list-bounce@xxxxxxxxxxxxx [mailto:si-list-bounce@xxxxxxxxxxxxx] On
Behalf Of Cortex Chen
Sent: Tuesday, November 30, 2004 10:31 PM
To: Kai Keskinen; ricbrook@xxxxxxxxx
Cc: si-list@xxxxxxxxxxxxx
Subject: [SI-LIST] Re: symmetry vs length matching for diff signals


Dear Kai,

For some aspect, I agree with your speaking.
In detail, there are some unknown for me as below:
As your said that  If the differential impedance is much less than twice =
the single ended impedance for the same track width, (i.e. 50 single, 90 =
differential)
It means as the equation: Zdiff =3D 2 * Zodd =3D 2 * (Z11- Z12) However,
even if impedance occurs (50 Ohms single, 97-100 differential), = I think
that the min (intra-pair) spacing may be the critical value not = loosely
coupled. If the spacing is more than the critical value, then the it becomes
= loosely coupled.  =20 You could observe that differential impedance will
be in saturation = region if the spacing is significantly more than the
critical value as = below example. I like to seek how to get the critical
value and the relationship = between the critical value and tightly coupled.

For example (reference only):

<Zo> 55 ohms (W: 5 mils)

<Zdiff> 100 ohms (target)

Trace Width  Spacing  Trace Width       Zdiff
         5             7               5                94.xx
         5             9               5                98.xx =20
         5            11              5                101.xx
         5            13              5                103.xx=20
         5            15              5                104.xx=20
         5            20              5                106.xx
         5            30              5                108.xx=20
         ...            ...             ...                ...
         ...            ...             ...                ...=20

Regards,

Cortex
         =20
-----Original Message-----
From: Kai Keskinen [mailto:kalevi@xxxxxxxxxx]
Sent: Wednesday, December 01, 2004 8:06 AM
To: ricbrook@xxxxxxxxx; Cortex Chen
Cc: si-list@xxxxxxxxxxxxx
Subject: RE: [SI-LIST] Re: symmetry vs length matching for diff signals


One quick way to determine loose or close coupling is to look at the =
single ended and differential impedances. If the differential impedance is
much less than twice the single ended impedance for the same track width, =
(i.e. 50 single, 90 differential), you have closely coupled lines. If the
impedance is slightly less (i.e. 50 Ohms single, 97-100 differential, = you
are loosely coupled). The loosely coupled pair is easier to route with
minimal differential impedance discontinuities if you have to go around =
vias or other obstructions by breaking up the diff pair.



-----Original Message-----
From: si-list-bounce@xxxxxxxxxxxxx [mailto:si-list-bounce@xxxxxxxxxxxxx]On
Behalf Of Rick Brooks
Sent: Tuesday, November 30, 2004 6:34 PM
To: Cortex.Chen@xxxxxxxxxxxx
Cc: si-list@xxxxxxxxxxxxx
Subject: [SI-LIST] Re: symmetry vs length matching for diff signals


I'm not sure this is what you are looking for or not...

There is a description in Ron Poon's book: Computer Circuits Electrical
Design, pg 198. He defines a magnetic coupling coefficient km and a
capacitive coupling coefficient kc with regard to coupled transmission lines

km =3D Lm/(SQRT(L1*L2))
kc =3D Cm/(SQRT(C1*C2))

Lm and Cm are mutual inductance and mutual capacitance per unit length L1
and L2 are self inductance and capacitance per unit length.

As a rough guideline: if km and kc are less than 0.2, the lines are said =
to have "loose" coupling.


I hope it helps,
- Rick






At 07:30 PM 11/30/2004 +0800, Cortex Chen wrote:
>Dear Abe Riazi,
>How to determine the tightly and loosely coupled pairs?
>
>Regards,
>
>Cortex
>
>
>
>
>------------------------------------------------------------------
>To unsubscribe from si-list:
>si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
>
>or to administer your membership from a web page, go to:
>//www.freelists.org/webpage/si-list
>
>For help:
>si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
>
>List FAQ wiki page is located at:
>                 http://si-list.org/wiki/wiki.pl?Si-List_FAQ
>
>List technical documents are available at:
>                 http://www.si-list.org
>
>List archives are viewable at:
>                 //www.freelists.org/archives/si-list
>or at our remote archives:
>                 http://groups.yahoo.com/group/si-list/messages
>Old (prior to June 6, 2001) list archives are viewable at:
>                 http://www.qsl.net/wb6tpu
>

------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field

List FAQ wiki page is located at:
                http://si-list.org/wiki/wiki.pl?Si-List_FAQ

List technical documents are available at:
                http://www.si-list.org

List archives are viewable at:
                //www.freelists.org/archives/si-list
or at our remote archives:
                http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu




------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field

List FAQ wiki page is located at:
                http://si-list.org/wiki/wiki.pl?Si-List_FAQ

List technical documents are available at:
                http://www.si-list.org

List archives are viewable at:
                //www.freelists.org/archives/si-list
or at our remote archives:
                http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu





------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field

List FAQ wiki page is located at:
                http://si-list.org/wiki/wiki.pl?Si-List_FAQ

List technical documents are available at:
                http://www.si-list.org

List archives are viewable at:
                //www.freelists.org/archives/si-list
or at our remote archives:
                http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu



------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field

List FAQ wiki page is located at:
                http://si-list.org/wiki/wiki.pl?Si-List_FAQ

List technical documents are available at:
                http://www.si-list.org

List archives are viewable at:     
                //www.freelists.org/archives/si-list
or at our remote archives:
                http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  

Other related posts: