Hello all, I do have a stupid question, maybe you can enlighten me .... Assuming a 6 layer board (Sig1 / GND / Sig2 / / Sig3 / Power / Sig4) with some single ended ustrip and stripline transmissionlines teststructures on all 4 signal layers. There are no passive components on the PCB (e. g. no C) My probes do have a signal and a GND pin. All teststructures does have a signal pad and a GND pad for contacting with the probe. Therefor I'm fine with Sig1 and Sig2! both are nice GND referenced, therefore I do not expect a problem with the measurements there! But Signal 3 and 4 are Power referenced. And so far there is not too much AC short between PWR and GND plane. The distance between this planes is > 30 mil, therefore I would expect the most AC short coming from the Vias. And now I'm not really sure what happens, if I'm doing a VNA / TDR / TDT measurement on Sig3 and Sig4, which are Power referenced, as my measurement ground is connected to the GND plane on the board..... Can the results tell me something, or can I forget the results completly ??? Is there a difference for VNA / TDR or TDT Measurments in this case ? thanks Hermann ------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field or to administer your membership from a web page, go to: //www.freelists.org/webpage/si-list For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List technical documents are available at: http:/www.si-list.org List archives are viewable at: //www.freelists.org/archives/si-list or at our remote archives: http://groups.yahoo.com/group/si-list/messages Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu