[SI-LIST] measuring DC elec. chs

  • From: Canes Venatici <starsilic@xxxxxxxxx>
  • To: si-list@xxxxxxxxxxxxx, si-list@xxxxxxxxxxxxx
  • Date: Fri, 27 Oct 2006 03:48:51 -0700 (PDT)

Hi,
I'm into chracterizing i/o cells. I want to know how to measure DC specs like 
Vih,Vil,Voh,Vol. 
Suppose, I f I know worst case Ioh or Iol then, can I load the o/p of the cell 
with that current, and
see how much is the voltage available at that load and treat it as Voh/Vol. 
But as per Jan Rabaey book (dig. Int. circuits) I could see, its proposed to 
use the DC trans. curves 
and the voltage corresponding to unity slope in curve is assumed to be Voh/l. 
Could anyone clarify on this.
Regards,
Canes




------------------------------------------------------------------