Neither case are bounded problems. Steve. On 6/10/2014 6:25 AM, Sipe, Dennis (ES) wrote: > Hello all. > The equation for impedance calculation of a single via is the one for coax > cable. > I cannot find one for a diff-pair via; two vias within an oval anti-pad. > I could use HFSS to do the calculations, but a simple equation should fall > out from that. > Can anyone point to a reference? Google was not my friend today. > > Thanks, > Dennis > > > > > ------------------------------------------------------------------ > To unsubscribe from si-list: > si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field > > or to administer your membership from a web page, go to: > //www.freelists.org/webpage/si-list > > For help: > si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field > > > List forum is accessible at: > http://tech.groups.yahoo.com/group/si-list > > List archives are viewable at: > //www.freelists.org/archives/si-list > > Old (prior to June 6, 2001) list archives are viewable at: > http://www.qsl.net/wb6tpu > > > -- Steve Weir IPBLOX, LLC 1580 Grand Point Way MS 34689 Reno, NV 89523-9998 www.ipblox.com (775) 299-4236 Business (866) 675-4630 Toll-free (707) 780-1951 Fax All contents Copyright (c)2013 IPBLOX, LLC. All Rights Reserved. This e-mail may contain confidential material. If you are not the intended recipient, please destroy all records and notify the sender. ------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field or to administer your membership from a web page, go to: //www.freelists.org/webpage/si-list For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List forum is accessible at: http://tech.groups.yahoo.com/group/si-list List archives are viewable at: //www.freelists.org/archives/si-list Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu