Are you certain the clock signal is the culprit?
Dave Cuthbert
On May 17, 2012 12:53 PM, "Joel Brown" <joel@xxxxxxxxxx> wrote:

> I am having an EMI problem with the second harmonic of a 65 MHz clock.
> There is a strong emission at 130 MHz.
> What is most likely causing the second harmonic and how can I reduce it?