Hi Have you provided the correct material information? Especially the dielectric constant. This can help you correlect the result. BR Trina On Aug 1, 2013 11:38 PM, "ye tao" <taoye000@xxxxxxxxx> wrote: > with agilent TDR,this via is 47 ohm,the sim model Dimensions is the real > size,I Sliced via and measured. > So,I think HFSS TDR is not very exactly,the result of simulation is higher > than measure 2~3 ohm,Do you experience such problems?I know increase the > antipad can fix it,but how simulate the via impedance,According 53 ohm > maybe better? > I simulated the trace line use hfss tdr,the result is almost same with > test,but the via is different,and I alter window function no improvement. > > ------------------------------------------------------------------ > To unsubscribe from si-list: > si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field > > or to administer your membership from a web page, go to: > //www.freelists.org/webpage/si-list > > For help: > si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field > > > List forum is accessible at: > http://tech.groups.yahoo.com/group/si-list > > List archives are viewable at: > //www.freelists.org/archives/si-list > > Old (prior to June 6, 2001) list archives are viewable at: > http://www.qsl.net/wb6tpu > > > ------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field or to administer your membership from a web page, go to: //www.freelists.org/webpage/si-list For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List forum is accessible at: http://tech.groups.yahoo.com/group/si-list List archives are viewable at: //www.freelists.org/archives/si-list Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu