[SI-LIST] Re: Shielding clock traces on PCB's

  • From: "Andrew Ingraham" <a.ingraham@xxxxxxxx>
  • To: "si-list" <si-list@xxxxxxxxxxxxx>
  • Date: Sun, 7 Jan 2007 18:02:29 -0500

> Guard traces ar great ways to make accidental band pass filters.  Why
> would anyone advise using them to control cross talk?

Because the word hasn't gotten around to most electrical engineers that it
doesn't work like they think it should.  So it continues to be done, and
many engineers wouldn't think there is anything wrong with it.

On first glance it seems like a reasonable thing to do, akin to putting a
shield around a wire, turning it into coax.  Reality is another matter.

Andy


------------------------------------------------------------------