[SI-LIST] Re: Problem with Ni plated transmission line

  • From: Daniel Kuchta <kuchta@xxxxxxxxxx>
  • To: si-list@xxxxxxxxxxxxx
  • Date: Fri, 14 Mar 2003 14:09:44 -0500





Thank you all for your help.

The consensus is that using Ni on transmission lines is a bad thing (for
low loss lines) and not that anything went wrong with my particular board
plating.

Now I need to find a good Ni etchant, one that doesn't etch Cu  :-)