Hi all,
I want to estimate one p2p net with Hspice, the structure is simple p2p net 
like as following: IC_buffer_output <--> transmission line <--> IC_buffer_input.
After I finished the whole structure, one strange question appears when I 
running the *.sp file. The error note given is as following: BSIM3 Fatal 
**error** Effective channel width <= 0.
I can't find what is wrong with the file, so I do some test through cutting the 
path as following 4 steps: (1) cut the connection between buffer_input and 
transimission line; (2)add one C_loading to the end of transimission line and 
run the simulation, the result is ok; (3)stimulating the buffer_input directly, 
it works also rightly. (4)However, as described before, when I connected the 
whole channel(buffer_output + transimission line + buffer_input), it doesn't 
work.
Appreciate your advice very much! Thanks firstly!

Best Regards!

Stephen


------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field

List FAQ wiki page is located at:
                http://si-list.org/wiki/wiki.pl?Si-List_FAQ

List technical documents are available at:
                http://www.si-list.org

List archives are viewable at:     
                //www.freelists.org/archives/si-list
or at our remote archives:
                http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  

Other related posts: