[SI-LIST] Re: Often overlooked effect of ground breaks

  • From: "Tom Biggs" <tbiggs@xxxxxxxxxxxxxxxxxxxxx>
  • To: <si-list@xxxxxxxxxxxxx>
  • Date: Wed, 11 Dec 2002 15:32:57 -0800

I know the affect of a trace routed over a break in a power plane.
 
I'm wondering how much the effect is mitigated if the power plane is 2
mils separated from a ground plane, using buried capacitance. Would the
return current be able to 'jump' over the break by going through the
'buried capacitor' to the ground plane and back?
 
   -tom

------------------------------------------------------------------