In my E-mail to the list on 4/19, item 5, I implied Linpar+Multlin was 
required to output S-parameters. As was noted by Chris Cheng, Linpar alone is 
required to output S-parameters for multiple, coupled, lossy T-lines. Sorry if 
I 
misled anyone. The main benefit of Multlin is to take LCRG parameter matrices 
(from ANY program that will produce them) and convert them into SPICE (actually 
PSPICE) format using Laplacian-bbased techniques. The result is a well behaved, 
bilateral, coupled network of interconnects that exhibits frequency dependent 
dielectric and skin effect losses. 

Michael L. Conn
Owner/Principal Consultant
Mikon Consulting

*** Serving Your Needs with Technical Excellence ***


------------------------------------------------------------------