[SI-LIST] LVDS RECEIVER IBIS MODEL

  • From: Peter LaFlamme <plaflamm@xxxxxxxx>
  • To: si list <si-list@xxxxxxxxxxxxx>
  • Date: Thu, 25 Jul 2002 11:08:38 -0400

Hi All,
I posed the question below to the ibis reflector and received a few responses. 
I am unsure if any will work for sure.
I figured that there may be people on the SI reflector that would have 
knowledge of how to implement this.

I appreciate any help you can offer.


Regards, 
Peter

-- 
Peter LaFlamme

Applied Micro Circuits Corp.
System Applications Engineer
200 Minuteman Rd, 3rd Floor
Andover, MA 01810

978-247-8470 phone
978-623-0055 Fax


___________________________________________________________


Question: 

I am tasked with creating an IBIS model for an LVDS receiver cell that has an 
internal 100
ohm termination between the P and N nodes. I had asked Bob Ross about this a 
while ago and
as usual he was very helpful. From his response I used the following
implementation: 

|****************************************************************
|                       Component:  LVDSRCV
|****************************************************************
|
[Component]      LVDSRCV
[Manufacturer]   AMCC
| 
| 
|
[Package]
|  variable       typ          min           max
R_pkg            1E-3          NA            NA
L_pkg            1E-9          NA            NA
C_pkg            1E-12          NA            NA
|
[Pin]        signal_name     model_name         R_pin   L_pin   C_pin
  1             PAD          lvdsrcv            NA      NA      NA
  2             PADN         lvdsrcv            NA      NA      NA
| 
[Series Pin Mapping]    pin_2   model_name      function_table_group
1                     2           rterm_100

| 
[Diff_pin]      inv_pin     vdiff     tdelay_typ    tdelay_min    tdelay_max
| 
   1               2          0.2          0             0             0

[Model]  rterm_100
C_comp                   0.1pF   0.1pF  0.1pF

Model_type  Series
|variable        R(typ)  R(min)  R(max)
[R Series]      100     80      120

[Temperature Range]     25.00    125.00    0.00
[Voltage Range]         1.800    1.650   1.950

****************************************************************************************


I was able to get the model past the IBIS checker but my simulations did not 
show the 100
ohm terminator. I was using a tool which I believe does not support this 
implementation
(no need to mention names). I have seen other implementations where I believe
a "Dynamic clamp" is used to model the termination behavior, but I am unsure. 
Can anyone
guide me to some reference material or weigh in with your experience or help.
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field

List archives are viewable at:     
                //www.freelists.org/archives/si-list
or at our remote archives:
                http://groups.yahoo.com/group/si-list/messages 
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  

Other related posts: