Hi all,
I'm designing a test board that will have differential trace widths of 4 mil
and I want to connect SMA connectors to them, but I'm not sure what connector
would be suitable as the ones I've found have connector widths that are neither
equal to or smaller than the trace widths, as well as the recommended pad sizes
are much larger. For an RF design I did at Uni, I just added a quarter wave
transformer to provide the matching at the operating frequency; is it still
possible to do this with a high-speed design with a 200 ps rise time (5 GHz)
signal?
Or can anyone recommended a way to connect VNA coaxial cables to a PCB with
trace widths around 4 mils, such that the Zo is maintained.
Thanks,
--
Hakim Sellaoui
Associate Hardware Engineer
DisplayLink (UK) Limited
Tel: +44 (0)1223 443920
Fax: +44 (0)1223 443921
E: hakim.sellaoui@xxxxxxxxxxxxxxx<mailto:hakim.sellaoui@xxxxxxxxxxxxxxx>
W: http://www.displaylink.com/
140 Science Park, Milton Road,
Cambridge, CB4 0GF,
United Kingdom.
Registered in England No. 04811048
DisplayLink Corp.
A US incorporated company.
480 S. California Avenue Ste 305, Palo Alto, CA 94306, USA.
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list
For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
List forum is accessible at:
http://tech.groups.yahoo.com/group/si-list
List archives are viewable at:
//www.freelists.org/archives/si-list
Old (prior to June 6, 2001) list archives are viewable at:
http://www.qsl.net/wb6tpu