Hello, Susan,

Not sure if others have answered your question yet.  The answer is almost
always "this is a problem".

The simple fix is to add points to [both] clamp tables with 0.00A at 0.00V,
and additional 0A points out to 2*Vcc.  This forces correct
interpolation/extrapolation by all tools.  The only exception is when there
is already data in the table in the range 0-2Vcc, in which case one should
try to understand why the current is not 0A at the reference voltage for
that table.

Feel free to suggest to your  model provider that they submit their IBIS
file to the IBIS Model Review Committee for comment
(http://www.eigroup.org/ibis/support.htm).

Best regards,
Lynne



"IBIS training when you need it, where you need it."

Dr. Lynne Green
Green Streak Programs
http://www.greenstreakprograms.com
425-788-0412
lgreen22@xxxxxxxxxxxxxx



-----Original Message-----
From: si-list-bounce@xxxxxxxxxxxxx [mailto:si-list-bounce@xxxxxxxxxxxxx] On
Behalf Of Susan George
Sent: Friday, November 14, 2008 3:23 PM
To: si-list@xxxxxxxxxxxxx
Subject: [SI-LIST] IBIS warning

Hi all,
       Is it ok to have IBIS warning "“POWER Clamp : Typical value never
becomes zero”.
If not, how do we fix this.Please advise.
 
Thanks
SJ

      
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field


List technical documents are available at:
                http://www.si-list.net

List archives are viewable at:     
                //www.freelists.org/archives/si-list
or at our remote archives:
                http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  

------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field


List technical documents are available at:
                http://www.si-list.net

List archives are viewable at:     
                //www.freelists.org/archives/si-list
or at our remote archives:
                http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  

Other related posts: