Dear Suresh K., this problem happens quite often on IBIS files wich are automatically generated - independed from the simulator you are using beacuse these messages are caused from the "official" IBIS Golden Parser (which is part of many EDA applications reading IBIS). It states that the IBIS file has problems in the content as IBIS demands in the spec that the the DC end points (calculated from the I-V tables must match the V-T end points (logic levels) with some variance. If the variance/error is within 2% you will just get a warning, otherwise an error, in your models the difference is seriously big. You can either correct your model by hand - but even as well it might be worth to contact IDT regarding the quality of this IBIS file. Feel free to contact me offline on further details how the file is read/processed in Hot-Stage. Kind regards Ralf Bruening ------------------------------------------------------------- Ralf Bruening - Product Manager - ZUKEN EMC Technology Center High Speed Solution Business - Vattmannstr.3 -33100 Paderborn Phone: +49 5251 150 600 (direct: 621) - FAX: +49 5251 150 700 Mobile: +49 170 4228512 - Alternative Mobile: +49 172 9070675 Email: ralf.bruening@xxxxxxxx - WWW: http://www.zuken.com ------------------------------------------------------------- Monday, November 17, 2003, 10:37:21 AM, you wrote: SK> Hi Gurus, SK> Warm Wishes to all ...... SK> I'm a beginner for SI Analysis and I need some clarification SK> about the Error of IBIS Model(71V2546-SRAM),which I'm getting when I SK> Import it into the Zuken's Hotstage tool Constraint Manager-Simulation SK> Library. SK> Actully I'm using the model ,which I downloaded from IDT website. SK> Please look into the error message below and give your precious SK> suggestions, SK> ERROR- Model IOPAD2546Z: The [Rising Waveform] SK> with [R_fixture]=50 Ohms and [V_fixture]=1.5V SK> has TYP column DC endpoints of 0.50V and 2.21v, but SK> an equivalent load applied to the model's I-V tables yields SK> different voltages ( 2.13V and 2.69V), SK> a difference of 288.80% and 84.70%, respectively. SK> ERROR- Model IOPAD2546Z: The [Falling Waveform] SK> with [R_fixture]=50 Ohms and [V_fixture]=1.5V SK> has TYP column DC endpoints of 0.50V and 2.21v, but SK> an equivalent load applied to the model's I-V tables yields SK> different voltages ( 2.13V and 2.69V), SK> a difference of 288.98% and 84.70%, respectively. SK> WARNING- Model 'IOPAD2546Z': TYP VI curves cannot drive through SK> Vmeas=1.25V SK> given load Rref=50 Ohms to Vref=1.5V SK> ERROR- Model IOPAD2546Z: The [Rising Waveform] SK> with [R_fixture]=50 Ohms and [V_fixture_min]=1.5V SK> has MIN column DC endpoints of 0.53V and 2.11v, but SK> an equivalent load applied to the model's I-V tables yields SK> different voltages ( 2.04V and 2.54V), SK> a difference of 304.74% and 86.47%, respectively. SK> ERROR- Model IOPAD2546Z: The [Falling Waveform] SK> with [R_fixture]=50 Ohms and [V_fixture_min]=1.5V SK> has MIN column DC endpoints of 0.53V and 2.11v, but SK> an equivalent load applied to the model's I-V tables yields SK> different voltages ( 2.04V and 2.54V), SK> a difference of 304.74% and 86.47%, respectively. SK> WARNING- Model 'IOPAD2546Z': MIN VI curves cannot drive through SK> Vmeas=1.25V SK> given load Rref=50 Ohms to Vref=1.5V SK> ERROR- Model IOPAD2546Z: The [Rising Waveform] SK> with [R_fixture]=50 Ohms and [V_fixture_max]=1.5V SK> has MAX column DC endpoints of 0.48V and 2.32v, but SK> an equivalent load applied to the model's I-V tables yields SK> different voltages ( 2.22V and 2.83V), SK> a difference of 283.59% and 82.91%, respectively. SK> ERROR- Model IOPAD2546Z: The [Falling Waveform] SK> with [R_fixture]=50 Ohms and [V_fixture_max]=1.5V SK> has MAX column DC endpoints of 0.48V and 2.32v, but SK> an equivalent load applied to the model's I-V tables yields SK> different voltages ( 2.22V and 2.83V), SK> a difference of 283.59% and 82.74%, respectively. SK> WARNING- Model 'IOPAD2546Z': MAX VI curves cannot drive through SK> Vmeas=1.25V SK> given load Rref=50 Ohms to Vref=1.5V SK> Errors : 6 SK> Warnings: 6 SK> File Failed SK> Thanks & Regards, SK> Suresh.K, SK> Vth EDA Lab, SK> C-DOT, SK> Bangalore-52. SK> ------------------------------------------------------------------ SK> To unsubscribe from si-list: SK> si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field SK> or to administer your membership from a web page, go to: SK> //www.freelists.org/webpage/si-list SK> For help: SK> si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field SK> List technical documents are available at: SK> http:/www.si-list.org SK> List archives are viewable at: SK> //www.freelists.org/archives/si-list SK> or at our remote archives: SK> http://groups.yahoo.com/group/si-list/messages SK> Old (prior to June 6, 2001) list archives are viewable at: SK> http://www.qsl.net/wb6tpu ------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field or to administer your membership from a web page, go to: //www.freelists.org/webpage/si-list For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List technical documents are available at: http:/www.si-list.org List archives are viewable at: //www.freelists.org/archives/si-list or at our remote archives: http://groups.yahoo.com/group/si-list/messages Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu