Vijay, TIME is the current timestep in the simulation. regards, scott -- Scott McMorrow Principal Engineer SiQual, Signal Quality Engineering 18735 SW Boones Ferry Road Tualatin, OR 97062-3090 (503) 885-1231 http://www.siqual.com mvvijay wrote: > Hi > > Can anybody Pls explain me the below command in Hspice > > .PRINT TRAN > + V_sweep = PAR('(sa_typ-sb_max)*(3*(TIME-Sp_d)/(Sp_t-Sp_d)-1)') > > I know PSpice. > sa_typ, sb_max, sp_t, sp_d are defined using .PARAM command. But TIME is > missing in .param statements. > Is it a keyword in Hspice? How the Hspice machine will execute this command? > What it will take for TIME? > Pls help me. > Thanks in advance > > Best Rgds > --Vijay > > ------------------------------------------------------------------ > To unsubscribe from si-list: > si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field > > or to administer your membership from a web page, go to: > //www.freelists.org/webpage/si-list > > For help: > si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field > > List archives are viewable at: > //www.freelists.org/archives/si-list > or at our remote archives: > http://groups.yahoo.com/group/si-list/messages > Old (prior to June 6, 2001) list archives are viewable at: > http://www.qsl.net/wb6tpu > ------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field or to administer your membership from a web page, go to: //www.freelists.org/webpage/si-list For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List archives are viewable at: //www.freelists.org/archives/si-list or at our remote archives: http://groups.yahoo.com/group/si-list/messages Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu