Hi Jesus,
   As a general rule of thumb, you'll want to include out to the 5th
harmonic in your measurements.  So, you're looking somewhere around a
3.5 GHz scope/probe bandwidth.

Best of luck,
Mike

-----Original Message-----
From: si-list-bounce@xxxxxxxxxxxxx [mailto:si-list-bounce@xxxxxxxxxxxxx]
On Behalf Of Santos Fernandez, Jesus
Sent: Friday, November 02, 2007 6:05 AM
To: si-list@xxxxxxxxxxxxx
Subject: [SI-LIST] HW Debugging

Hello all,
=20

We are designing a PCB with fastest transmission clock speed of 600MHz.

We have 1GHz oscilloscopes (and below)

=20

Do you think we will need additional test equipment for any required
design testing?

If you think so, will you, please, suggest which minimum equipment will
be necessary?

=20

Thank you in advance,

J. Santos

=20


------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field


List technical documents are available at:
                http://www.si-list.net

List archives are viewable at:    =20
                //www.freelists.org/archives/si-list
or at our remote archives:
                http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
 =20


*****************************************************************
*************
CONFIDENTIAL NOTE: This e-mail and any attachments may be 
confidential and protected by legal privilege. If you are not 
the intended recipient, be aware that you are hereby notified 
that any unauthorized review, use, disclosure, dissemination, 
distribution, or copying of this communication, or any of its 
contents, is strictly prohibited. If you have received this 
email in error, please notify us immediately by replying to the 
sender and deleting this copy and the reply from your system. 
Thank you for your cooperation. 

EXPORT CONTROLLED DOCUMENT 
This document may contain information whose export is restricted 
by the Arms Export Control Act (Title 22, U.S.C., Sec 2751 Et 
Seq.) or the Export Administration Act of 1979, as amended, 
(Title 50, U.S.C., App. 2401, Et. Seq.) Violations to these 
export laws are subject to severe criminal penalties.  

All technical data forwarded by VT Miltope to its suppliers is 
EXPORT CONTROLLED. Supplier shall not disclose technical data in 
any form to a Foreign Person (including foreign person employees 
of Supplier), or export the technical data from the United 
States without U.S. Government authority and the written 
authorization of VT Miltope Contracts Department. 
*****************************************************************
*************
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field


List technical documents are available at:
                http://www.si-list.net

List archives are viewable at:     
                //www.freelists.org/archives/si-list
or at our remote archives:
                http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  

Other related posts: