The article describes very well how you can make sure that the radiation you 
Layout creates stays inside the PCB, but this comes with a cost and I'm not 
convinced that it is needed if your design is optimized for SI (especially on 
backplanes).
I only use edge plating if the customer requires it or if there is need for it 
(i.e. I know that there will be radiation inside) but that's very rare. On the 
Backplanes I've done without edge plating not a single one failed any EMC test 
and that ranges from DC to 100G Ethernet, Video routers, Media Gateways, Base 
Stations and many more low and high speed Systems. Daughtercards are a 
different story because there a more potential sources of radiation.

I'm not saying that edge plating doesn't work, I'm just saying that to my 
knowledge good backplane design doesn't require it.

Just my two cents.

BR
Gert

-----Original Message-----
From: si-list-bounce@xxxxxxxxxxxxx [mailto:si-list-bounce@xxxxxxxxxxxxx] On ;
Behalf Of Eric Bogatin
Sent: Thursday, January 19, 2017 3:11 PM
To: si-list@xxxxxxxxxxxxx
Cc: 'Eric Bogatin' <eric@xxxxxxxxxxxxxxx>; 'Hindle, Patrick' 
<phindle@xxxxxxxxxxxxx>; 'Love, Janine' <jlove@xxxxxxxxxxxxx>
Subject: [SI-LIST] Great article in SI Journal on emissions from backplanes

Hi folks-


If you have not done it yet, you'll want to visit the Signal Integrity
Journal: https://www.signalintegrityjournal.com/



This month, our own Bert Simonovich has a great article about controlling 
emissions from the edge of backplanes:
https://www.signalintegrityjournal.com/articles/292-controlling-electromagne
tic-emissions-from-pcb-edges-in-backplanes



You should consider signing up for the newsletter that comes out every 2 weeks 
to get a push notification of new articles:
https://www.signalintegrityjournal.com/user/new



And, if you want to spread the word about your own work, consider writing a 
piece for the SI J. Here are the writers guidelines:
https://www.signalintegrityjournal.com/submissions



Got an idea for a piece, drop a note to Pat Hindle, contact information at the 
end of the writer's guidelines.



And check out some of my columns:
https://www.signalintegrityjournal.com/blogs/4-eric-bogatin-signal-integrity
-journal-editor



All the content is free and open to anyone.



--eric







*******************************************************
Dr. Eric Bogatin

Dean,  <http://www.bethesignal.com/> Signal Integrity Academy

Editor,  <https://www.signalintegrityjournal.com/> Signal Integrity Journal,


Adjunct Prof, ECEE Univ of Colorado, Boulder

Director, Teledyne LeCroy Front Range Signal Integrity Lab

105 S Sunset St, Suite J

Longmont, CO 80501 USA

Twitter @beTheSignal
e:  <mailto:eric@xxxxxxxxxxxxxxx> eric@xxxxxxxxxxxxxxx

cell: 913-424-4333

 <http://www.bethesignal.com/> www.beTheSignal.com
******************************************************





------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field


List forum  is accessible at:
               http://tech.groups.yahoo.com/group/si-list

List archives are viewable at:
//www.freelists.org/archives/si-list

Old (prior to June 6, 2001) list archives are viewable at:
 http://www.qsl.net/wb6tpu



----------------------------------------
HARTING AG & Co. KG | Postfach 11 33, 32325 Espelkamp | Marienwerderstraße 3, 
32339 Espelkamp | www.HARTING.com
Generalbevollmächtigte Gesellschafterin: Dipl.-Hdl. Margrit Harting
Persönlich haftende Gesellschafter:
HARTING WiMa AG (Luxemburg) & Co. KG | Amtsgericht Bad Oeynhausen | HRA 8259 | 
Espelkamp, persönlich haftende Gesellschafterin: HARTING Führungs AG (Registre 
de Commerce et des Sociétés Luxembourg) | B 170749 | Luxemburg
Vorstand: Dipl.-Kfm. Philip F. W. Harting (Vorsitzender), Dipl.-Kffr. Maresa W. 
M. Harting-Hertz, Dipl.-Kfm. Dr.-Ing. E. h. Dietmar Harting, Dr. rer. nat. 
Frank Brode, Dipl.-Ing. (FH), Dipl.-Wirtsch.-Ing. (FH) Andreas Conrad, Dr. iur. 
Michael Pütz;
Sitz der Gesellschaft: Espelkamp | Amtsgericht Bad Oeynhausen | HRA 9021 | 
UST-ld Nr. DE812136745

------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field


List forum  is accessible at:
               http://tech.groups.yahoo.com/group/si-list

List archives are viewable at:     
                //www.freelists.org/archives/si-list
 
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  

Other related posts: