[SI-LIST] Emission

  • From: BRanjul@xxxxxxxxxxxxxx
  • To: si-list@xxxxxxxxxxxxx
  • Date: Mon, 9 Feb 2004 11:39:52 +0530

Dear all,
Please help me to sort out this problem.
While testing our equipment in the anechoic chamber in our place, we could 
notice that nearly 30db ambient noise present (say at 100Mhz) in the 
chamber before the equipment is tested.
Then , if the our equipment fails at 100Mhz for 0.5 db does it really 
fail? 
Or if the equipment passes by 1 db margin, does it really pass ?

Ranju

------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field

List technical documents are available at:
                http://www.si-list.org

List archives are viewable at:     
                //www.freelists.org/archives/si-list
or at our remote archives:
                http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  

Other related posts: