Let me save folks the trouble of emailing me regarding the frequency dependency of the loop inductance of a transmission line. What I took the question to mean was a "lumped" parameter value for a component. Best Regards Charles Grasso Compliance Engineer Echostar Communications Corp. Tel: 303-706-5467 Fax: 303-799-6222 Cell: 303-204-2974 Pager/Short Message: 3032042974@xxxxxxxxx Email: charles.grasso@xxxxxxxxxxxx -----Original Message----- From: Grasso, Charles=20 Sent: Wednesday, September 13, 2006 10:47 AM To: 'ramesh.k@xxxxxxxxxxx'; 'si-list@xxxxxxxxxxxxx' Subject: RE: [SI-LIST] Emc_FTT I am not sure what you're looking for. The inductance of a via is a physical property of the part independent of frequency (or rise time). What are you trying to accomplish? As a data point a typical Via Round 23 Drill 10 62 mils long has roughly 1nH of inductance. Best Regards Charles Grasso Compliance Engineer Echostar Communications Corp. Tel: 303-706-5467 Fax: 303-799-6222 Cell: 303-204-2974 Pager/Short Message: 3032042974@xxxxxxxxx Email: charles.grasso@xxxxxxxxxxxx -----Original Message----- From: si-list-bounce@xxxxxxxxxxxxx [mailto:si-list-bounce@xxxxxxxxxxxxx] On Behalf Of RameshK Cozerv IN HO Sent: Wednesday, September 13, 2006 1:05 AM To: si-list@xxxxxxxxxxxxx Subject: [SI-LIST] Emc_FTT =20 Hi Folks, =20 Can someone guide me,what will be the via size(Drill & Pad Size) to accomplish 10 to 20 nano henry drop for 5 ns rise and fall in fast transient time (Emc)? suggestions and advices are appreciated. =20 -Ramesh =20 ######################################################################## ############# Note: This message is for the named person's use only. It may contain confidential, proprietary or legally privileged information. No confidentiality or privilege is waived or lost by any mistransmission. If you receive this message in error, please immediately delete it and all copies of it from your system, destroy any hard copies of it and notify the sender. You must not, directly or indirectly, use, disclose, distribute, print, or copy any part of this message if you are not the intended recipient. ConZerv Systems Pvt. Ltd. and any of its subsidiaries each reserve the right to monitor all e-mail communications through its networks. Any views expressed in this message are those of the individual sender, except where the message states otherwise and the sender is authorized to state them to be the views of any such entity. Thank You. ######################################################################## ############# ------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field or to administer your membership from a web page, go to: //www.freelists.org/webpage/si-list For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List FAQ wiki page is located at: http://si-list.org/wiki/wiki.pl?Si-List_FAQ List technical documents are available at: http://www.si-list.org List archives are viewable at: =20 //www.freelists.org/archives/si-list or at our remote archives: http://groups.yahoo.com/group/si-list/messages Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu =20 ------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field or to administer your membership from a web page, go to: //www.freelists.org/webpage/si-list For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List FAQ wiki page is located at: http://si-list.org/wiki/wiki.pl?Si-List_FAQ List technical documents are available at: http://www.si-list.org List archives are viewable at: //www.freelists.org/archives/si-list or at our remote archives: http://groups.yahoo.com/group/si-list/messages Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu