[SI-LIST] Dk/Df value is increased very much after fabric progress

  • From: Hung Dang <hungdn.hcmut@xxxxxxxxx>
  • To: si-list@xxxxxxxxxxxxx
  • Date: Thu, 17 May 2018 08:21:51 +0700

Dear Expert,
When I run SI simulation, I apply Dk/Df of PCB material from datasheet.
After fabric progress, I measured on the actual board, Dk is increased
28.7% (3.65 --> 4.7) and 41.6%(0.012 --> 0.017) for Df when comparing with
value in datasheet.
So I have concerns below:

1/. What is the Dk/Df worst value which I should apply to simulation phase?
2/. Could you help to list some application note or paper which talk about
this issue?

Thank you so much.
-- 
-------------------------------------------------------------------------------
MS Hung-Dang Ngoc
Email: hungdn.hcmut@xxxxxxxxx <phandainghiamnc@xxxxxxxxx>
Phone: +84 1682 405 564
Skype/Facebook: hungdn.hcmut


------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to: