Hi Experts, A basic question on calculating rise time from ISI - In the IBIS file, the ramp data for a 3.3V buffer dV/dt_r is 700.2m/190.9p This is not 10-90% or 20-80% of 3.3V Do I take it as 700mV rise per 190psec and scale it to either 10-90% or 20-80%? In that case why not give the values directly. Regards -Hthesh ------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field or to administer your membership from a web page, go to: //www.freelists.org/webpage/si-list For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List forum is accessible at: http://tech.groups.yahoo.com/group/si-list List archives are viewable at: //www.freelists.org/archives/si-list Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu