Hi Bala,

if you terminate the SFP+ end with 100Ohm, then the resulting ipedance will be 
50Ohm (SFP+ transceiver 100Ohm parallel to 100Ohm resistor). I don't think this 
will reduce the return loss in any way.
You should check the SFP+ footprint, vias (if there are any) and BGA Footprint 
for high reflections. Did you cut out the GND plane underneath the SFP+ solder 
pad?

BR
Gert


--------------------------------------------------------------------------
Absender ist HARTING Electronics GmbH & Co. KG; Sitz der Gesellschaft: 
Espelkamp; Registergericht: Bad Oeynhausen; Register-Nr.: HRA 5596; persönlich 
haftende Gesellschafterin: HARTING Electronics Management GmbH; Sitz der 
Komplementär-GmbH: Espelkamp; Registergericht der Komplementär-GmbH: Bad 
Oeynhausen; Register-Nr. der Komplementär-GmbH: HRB 8808; Geschäftsführer: 
Edgar-Peter Duening, Torsten Ratzmann, Dr. Alexander Rost
-----Ursprüngliche Nachricht-----

Von: si-list-bounce@xxxxxxxxxxxxx [mailto:si-list-bounce@xxxxxxxxxxxxx] Im 
Auftrag von bala
Gesendet: Freitag, 29. Juli 2011 12:12
An: si-list@xxxxxxxxxxxxx
Betreff: [SI-LIST] Return loss on 10G signals

Hi Experts,

We have XAUI Tranciver and SFP+ in our design.While simulating for the total 
channel loss,we saw some return loss issues.Is this okay to add
100 ohm termination at the SFP+ end.Is this acepatble.its 10G signals.Please 
help.
--
bala
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field


List technical documents are available at:
                http://www.si-list.net

List archives are viewable at:     
                //www.freelists.org/archives/si-list
 
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  


------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field


List technical documents are available at:
                http://www.si-list.net

List archives are viewable at:     
                //www.freelists.org/archives/si-list
 
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  

Other related posts: