[rodgersorgan] Re: Sticky Oscillators while tuning....

  • From: OrganMD@xxxxxxx
  • To: rodgersorgan@xxxxxxxxxxxxx
  • Date: Sun, 27 Jul 2003 00:41:05 EDT

Hi .............
I will add my 2 cents worth and 25 years of field time.  The wound core and 
the ferrite base are attached with silicon sealant.  I have seen cases where a 
little of the sealant made it to the matting surfaces of the cap and base, a 
bad thing.  You likely will have to remove the nut and tensioning spring then 
very carefully pry the cap from the base.  Clean up the mess and reassemble.  
Look very closely to the edges it only takes a drop of the stuff to weld the 
cap to the base.

Good luck

Bill


!
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Find new MIDI music and Guides to Rodgers Organs at www.frogmusic.com

To post send messages to: rodgersorgan@xxxxxxxxxxxxx

To unsubscribe or change mail delivery (digest, vacation)
go to www.frogmusic.com/rodgersmem.html


Other related posts: