 The system will not source anywhere near 40 amps reliably. The batteries used 
simply are not up to it. (7AH sealed lead acid)

Have you considered series wiring, rather than parallel? You would need low 
resistance ignitors, but the system would have a better chance of firing. I 
prefer series anyway, but have not tried more than 5 motors at a time.

For a project with major requirements like that you should probably have your 
own boost box, with the ROC system picking up a relay. And plan to use a car 
battery to source that much current.
Dave Smith

    On Monday, June 4, 2018, 11:13:32 PM PDT, James Eadie 
<falconheavy@xxxxxxxxxxx> wrote:  
 
 
I’d like to do a seven-motor cluster at ROCstock, pulling about 35-40 amps. 
What are the launch controller relays rated at? Does the club have an at-pad 
booster box for clusters?

  

James Eadie
  